黄富祥,徐永福,王维和,董超华. 2006. 臭氧吸收参数数据库精度检验和验证[J]. 气象学报, 64(2):229-235, doi:10.11676/qxxb2006.023
臭氧吸收参数数据库精度检验和验证
CHECKING AND VALIDATING THE ABSORPTIONCOEFFICIENTS OF OZONE IN THE UV BAND
投稿时间:2005-06-27  修订日期:2005-09-16
DOI:10.11676/qxxb2006.023
中文关键词:  臭氧,分子吸收截面,臭氧吸收带,TOMRAD模式
英文关键词:ozone, molecular absorption cross-section, ozone absorption band, TOMRAD model
基金项目:国家卫星气象中心事业课题《星载紫外臭氧探测仪及其反演方法研究》
作者单位
黄富祥 中国气象局中国遥感卫星辐射测量和定标重点开放实验室 国家卫星气象中心北京100081 
徐永福 中国科学院大气物理研究所大气边界层物理和大气化学国家实验室北京100029 
王维和 中国气象局中国遥感卫星辐射测量和定标重点开放实验室 国家卫星气象中心北京100081 
董超华 中国气象局中国遥感卫星辐射测量和定标重点开放实验室 国家卫星气象中心北京100081 
摘要点击次数: 3175
全文下载次数: 3333
中文摘要:
      利用国际权威期刊上发表的臭氧吸收截面观测数据,检验和验证了现有的紫外臭氧探测仪TOMRAD正演模式臭氧吸收参数数据库。结果表明,在Hartley臭氧吸收带上,观测数据与数据库参数吻合状况很好;而在Huggins臭氧吸收带上,观测数据与数据库参数在部分波长上存在较大偏差,某些波长上的偏差达到50%以上。鉴于此,FY-3紫外臭氧探测仪资料处理计算中,选取臭氧吸收参数,必须特别慎重。
英文摘要:
      The knowledge of the absorption coefficients of ozone in the UV band is of major importance for the monitoring of the atmospheric ozone layer using the solar backscattering ultraviolet technique. In order to gain significant measurements of atmospheric ozone, accurate ozone absorption coefficients should be derived from the high accurate laboratory measurements of absorption cross-section of ozone. To make sure the absorption coefficients are be precise, in the present paper, we check and validate the now existing ozone coefficients bank in the American TOMRAD model using these high accurate and high resolution laboratory measurements data published in the international journals in the past few years . From 1980s, many papers on laboratory absorption cross of ozone measurement data with different spectrum resolution and measurement accuracy were published in all kinds of international journals. Among these, data from French Brion et al have much more higher spectrum resolution and measurement accuracy than others. First, we randomly selected some wavelengths from Hartley and Huggins band respectively. For every wavelength, we built the regression model of the ozone absorption cross-section to temperature with the widely used polynomial formulas and get the ozone absorption coefficients for these wavelengths. To check the now existing ozone absorption coefficients, we compared the calculated coefficients with that from the American TOMRAD model coefficient bank. Second, to validate the coefficients of the TOMRAD model, at these randomly selected wavelengths, we calculated the ozone absorption cross-section under the same temperature with that of Ozone UV Spectroscopy. II. Absorption cross-sections and temperature dependence, and compared the calculated data with the laboratory measurement data in Ozone UV Spectroscopy. II. Absorption cross-sections and temperature dependence .The results show that the calculated cross-section at Hartley band using coefficients from the TOMRAD model is quite consistent with that laboratory measurement from Ozone UV Spectroscopy. II. Absorption cross-sections and temperature dependence, the variance at most randomly selected wavelengths is smaller than 3%; However, in the Huggins band, the variance at most wavelengths is much more bigger, at some wavelengths, the variance is bigger than 50%. Since, data from Ozone UV Spectroscopy. II. Absorption cross-sections and temperature dependence have higher spectrum resolution and accurate than that data by Bass and Paur , from which the now existing ozone absorption coefficients were drawn, we have reasons to suspect the validity of the now existing ozone absorption coefficients at some wavelength in Huggins band.
HTML   查看全文   查看/发表评论  下载PDF阅读器